Riester ri-champion Smartpro Digital Sphygmomanometer
The Riester ri-champion® smartPRO+ Clinically validated blood pressure monitor, designed for fast and reliable readings. Advanced performance by indicating irregular heartbeat detection and average measurement function.
› Clinically validated
› Fast and low noise measurements
› Irregular heartbeat detection
› Average BP measurement function
› 200 measurements with one set of batteries
› Optional Bluetooth connectivity
› Optional mains adapter
› Automatic off function – if left idle for 3 minutes
› CE / FDA approved
› IP21 Water protection
Power Source: Four 1.5 V AA alkaline batteries
Battery Life: 200 Readings
Size of Meter w/o Cuff: 141 (L) x 121 (W) x 72 (H)mm, 350 g without batteries
Cuff Size: S (small): 15 – 24 cm (5.9 – 9.4 inches) with air tube 80 cm
W (Wide size): 24 – 43 cm (9.4 – 16.9 inches) with air tube 80 cm
Memory: Maximum 400 memory records
External Output: Bluetooth (ri-champion® smartPRO+ only)
(Frequency: 2.45 GHz, Bandwidth: 170 MHZ, Modulation: GFSK, ERP: 3.54 dBm)
Power Saving: Automatic power off if system idle for 3 minutes
Operating Conditions: 5°C to 40°C (41°F to 104°F), 15 % to 93 % relative humidity, 700 hPa to 1060 hPa
Storage / Transportation Conditions: -25°C to 70°C (-13°F to 158°F), 10 % to 95 % relative humidity
Power Supply Input: DC + 6 V / 1 A (max) via Power Plug
IP Classification: IP21
Heart Rate Range: 40 – 199 beat per minute
Systolic Measurement Range: 60 mmHg – 255 mmHg
Diastolic Measurement Range: 30 mmHg – 195 mmHg
Pulse Rate Measurement Range: 40 – 199 beats / minute
Maximum Inflation Pressure: 280 mmHg
Accuracy of Pressure: ±3 mmHg or ±2% of reading
Accuracy of Pulse rate: ±4% of reading
Measurement Unit: Either mmHg or KPa
This device has been tested to meet the electrical and safety requirements of:
IEC/EN 60601-1, IEC/EN 60601-1-2, EN 301 489-17, EN 301 489-1, EN 300 328.
Reference to Standards:
EN 1060-3, NIBP-requirements
IEC60601-1 General requirement for safety
IEC60601-1-2 Requirements for EMC
EN1060-4, NIBP clinical investigation
AAMI / ANSI / IEC 80601-2-30, ANSI/AAMI/ISO 81060-2, NIBP requirements
- Art. No. 1735-BT Blood pressure device ri-champion® smartPRO+ with BT and W-cuff
- Art. No. 1735 Blood pressure device ri-champion® smartPRO without BT, with W-cuff
- Art. No. 1736-BT Blood pressure device ri-champion® smartPRO+ with BT and S-cuff
- Art. No. 1736 Blood pressure device ri-champion® smartPRO without BT, with S-cuff
- Art. No. 12633 Cuff size W (24 - 43 cm)
- Art. No. 12632 Cuff size S (15 - 24 cm)
- Art. No. 12631 AC adaptor